When in Dental Manager, trying to generate CAM output / F7, an error message is shown:
"Manufacturing output could not be generated.
RawSTL: An error occurred while generating CAM output.
Error message: The specified path was not found."
Root cause: The path is not configured correctly in the Dental system control panel.
Solution: Proceed to Dental System Control Panel > system settings > Data output directories > Manufacturing output directory is currently defined as:
Verify the path is:
\\CO-LPT-PFL\3Shape Dental System Orders\ManufacturingDir\
Save and close DSCP > Open DS and generate CAMoutput / F7 again.
This should solve the issue; nevertheless, if it does not, proceed to verify by modifying the material and or creating a new order and going through the flow process again in order to generate the CAM output.